3.5 Additional functions
3.5.1 Minimum and Maximum functions (For COP and SPW modes)
TheTA500maintainsacontinuousrecordoftheminimumandmaximumreadingsofthe
functioncurrentlyselected.
1-TodisplaytheMinimumandMaximumreadings of themaindisplay, if notalready
selectedpress‘Secondary Function / Capture’ buttonmomentarily.
2-ToresettheMinimumandMaximumreadings,pressthe‘Power On/Off / Reset’ button
momentarily.Thesevaluesarealsoresetwhenturningtheuniton.
Note:
•For the tachometer function (RPM) all Minimum and Maximum readings on the
secondarydisplaysareshownwiththelastdigitroundedto“0”.
3.5.2 Spark KVolt calibration function (For COP mode only)
The TA500 requires the user to calibrate the instrument in order to measure spark
KVolt in Coil on Plug and Coil near Plug ignition systems. This calibration uses the
measurement values obtained during the procedure to find the optimal measuring
parametersor a particulartype ofignition module, andcompensates for differences in
waveformandsignalstrength.
• Once the TA500 has been calibrated on one of the ignition modules of the engine
beingdiagnosed,allthesubsequentmeasurementofsparkKVoltwillberelativetothe
calibrationvalue.
• TocalibratetheTA500,followtheprocedureasdescribedin‘3.4.2MeasuringCoilon
PlugandCoilnearPlugignitionsystems’.
Page9
3.4.2 Spark plug wire ignition systems
1-Turntheinstrumenton.
2-Ifnotalreadyin
SPW(SparkPlugWire)mode,selectitbypressingthe‘Ignition System’
button.
3-Selectthenumberofcyclesfortheengineundermeasurementbypressingthe‘
Engine
Cycles’buttonrepeatedlyuntilthedisplayshowsthecorrectsetting.
4-Select the measurement to show in the main display: RPM, spark burn time or
sparkKVolt.
5-Selectthemodeforthesecondarydisplay:MinimumandMaximumofthemaindisplay
orthecomplementarymeasurements.
6-Placethecapacitivepickupoveroneofthesparkplugwires,andproceedtoreadthe
measurementonthedisplay.
Sparkplugwire
Sparkplugwire
Capacitivepick-upat90°
Capacitivepick-upparallel
Fig.6-Capacitivepick-uponsparkplugwire
Page10
Important:
• InordertoobtainconsistentresultswhenmeasuringSparkKVoltonsparkplugwires,
thepositionofthecapacitivepick-uprelativetothesparkplugwireshouldbethe
sameforeverymeasurement.
•An easy way to obtain consistent measurements, is to position the capacitive
pick-upeitherat90°orparalleltothesparkplugwire(Fig5),andthenrepeatthe
samepositioningforeverysparkplugwire
•SparkburntimeandRPMmeasurementsarenotsensitivetotheexactpositionof
thecapacitivepick-uprelativetothesparkplugwire,butithastobeplacedsothe
instrumentiscapableofdetectingthesignal.
•When several spark plug wires are routed or bunched close together, the
capacitive pick-up may receive signals from several wires at the same time,
which could cause erroneous measurements. In these situations it may be
necessarytoseparatethewireundermeasurementfromtheothers,inordertoreduce
interferenceandobtainanaccuratemeasurement.
Notes:
• Immediatelyaftercalibration,theTA500willdisplayabaselinevalueof“10.0Spark
KVolt” by default.All the spark KVolt measurements obtained thereafter would be
relativestothe(value)moduleusedforcalibration.
•CalibrationdoesnothaveanyeffectonsparkburntimeorRPMmeasuredvalues
(theseareabsolute).
•IftheTA500is calibratedagain, theSpark KVoltvalues obtainedbefore andafter
calibrationmaynotbecomparable.
•If not calibrated, the TA500 may show a false ‘0.0 Spark KVolt’ reading when
measuringsparkKVoltonCoilonPlugandCoilnearPlugsystems.